Customization: | Available |
---|---|
Ice shape: | Square |
Control: | Electric |
Still deciding? Get samples of US$ 500/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | Unit size (L*W*H mm) |
Ice tray size (cm) | Ice production (kg/24H) | Ice storage (KG) | Cooling method | Compressor | Power (W) |
SIM-55 | 430*520*860 | 5*8 | 25 | 15 | Air-cooling / water-cooling | SECOP | 320W |
SIM-80 | 430*520*860 | 5*9 | 40 | 15 | Air-cooling / water-cooling | SECOP | 380W |
SIM-120 | 530*570*860 | 5*11 | 60 | 26 | Air-cooling / water-cooling | SECOP | 400W |
SIM-150 | 530*570*860 | 5*13 | 70 | 26 | Air-cooling / water-cooling | SECOP | 420W |
SIM-200 | 680*630*1050 | 5*18 | 90 | 65 | Air-cooling / water-cooling | SECOP | 600W |
SIM-280 | 680*630*1050 | 6*18 | 126 | 65 | Air-cooling / water-cooling | SECOP | 650W |
SIM-300 | 560*830*1520 | 12*13 | 136 | 150 | Air-cooling / water-cooling | SECOP | 750W |
SIM-400 | 560*830*1520 | 13*14 | 181 | 150 | Air-cooling / water-cooling | SECOP | 900W |
SIM-500 | 760*830*1650 | 11*18 | 227 | 250 | Air-cooling / water-cooling | Copeland / SECOP | 1180W |
SIM-600 | 760*830*1650 | 11*18 | 272 | 250 | Air-cooling / water-cooling | Copeland / SECOP | 1250W |
SIM-700 | 760*830*1770 | 13*18 | 318 | 250 | Air-cooling / water-cooling | Copeland / Taikang | 1350W |
SIM-800 | 760*830*1770 | 13*18 | 363 | 250 | Air-cooling / water-cooling | Copeland / Taikang | 1600W |
SIM-1000 | 760*830*1900 | 18*19 | 454 | 250 | Air-cooling / water-cooling | Copeland / Taikang | 1860W |
SIM-1500 | 1230*930*1910 | 13*18*2 | 681 | 480 | Air-cooling / water-cooling | Copeland / Taikang | 2800W |
SIM-2000 | 1230*930*2040 | 18*19*2 | 910 | 480 | Air-cooling / water-cooling | Taikang | 3680W |
Installation instructions:
1. the refrigerating machine placement
(1) the machine should be placed in the air circulation, safe and clean place.
(2) the machine should not be placed outdoor, unfavorable under direct sunlight and rain.Not near the heat source.
(3) the use of the machine environment cannot be lower than 5 ºC, no more than 38 ºC.
(4) around the machine should have enough space, especially the back not less than 250 mm.In order to machine the cooling.
(5) please adjust the machine at the bottom of the anchor bolt to ensure smooth placed level.
2. the installation of a water system
(1) please plug in accordance with local water source of drinking water standards.
(2) connected to the filter when necessary, in order to improve the standard of drinking water.
(3) the water supply system must meet the following conditions.
A. the lowest temperature 2 ºC, the highest do not exceed 38 ºC
B. water pressure the lowest 0.02 Mpa, the highest 0.8 Mpa
3. the installation of power supply
(1) the power supply must be consistent with the machine indicated on the nameplate.
(2) all lines must be in conformity with the national standard.
(3) must be reliable grounding, grounding wire must meet the electrical standards.
(4) voltage fluctuation may not exceed the rated voltage of plus or minus 10%.
Instructions:
1. ice making process
(1) must be checked before starting the automatic water supply device is normal, the tank to save water is reasonable (the machine factory has just the water level, the user can be reset).
(2) the plug in the power supply, ice making machine began to work, first of all, the pump running, the exhaust air pump has a short process) compressor started about two minutes later, into ice making machine.
(3) when to set the thickness of the ice thickness, ice plate probe began, electromagnetic valve start to work, water pump stop working, and the heat into the evaporator, about 1.5 minutes of ice.When I fall on the ice to the ice dampers inside out and open the magnetic reed switch.When magnetic reed switch closed again, the machine into the ice making process again.
(4) the compressor in the entire process of ice and ice off, don't stop.
(5) when water ice barrel for a full, magnetic reed switch cannot be automatically closed, the machine automatically stop working, and when taken enough ice, magnetic reed switch after reclosing time delay machine start after 3 minutes, back into the ice making process.
2. the thickness of ice bridge is
(1) the thickness of the ice bridge should be about 3 mm, between the probe and the evaporator international should be thicker than the actual thickness of the ice bridge 1.5 mm or so, mouth turn adjusting screw clockwise to increase the thickness of the ice bridge (screw rotation 1/3 circle ice bridge thickness change 1.5 mm).
(2) check the ice plate probe connections and bracket, should guarantee the free rotation after each process of ice can be returned to the right place.
The cause of the problem:
The ice maker compressor discontinuous work: 1, the voltage is too low.Check the power supply. 2, the contact point contact is not good. 3, the system pressure protection. 4, compressor starter malfunction. |
Lack of ice production 1, the capillary or expansion valve block. 2, high moisture system with mild ice wall. 3, ice making machine water supply is not enough. 4, lack of refrigerant or leakage. 5, evaporator spoils. |
Wet ice ice is not hard 1, the environment temperature is too high especially in the summer will have a kind of situation. 2, maintenance of machine refrigerant added. 3, plate ice machine water water supply is too large. 4, press the power shortage. |
Machine but not out of the ice 1, the baffle plate of water or no water enough. 2, speed reducer failure or gear motor. 3, system fault ice wall.Dirty plugging, etc. |
Ice machine leaking 1, Inlet valve supply water tray is too large. 2, connecting pipe is broken. 3, the coupling fault. 4, water level float valve failure. |
Too much noise 1, ice barrel fault ice skates. 2, brine concentration was not enough. 3, speed reducer failure. 4, fan fault. 5, noisy compressor. |
Water shortage alarm 1, filter plugging water joint. 2, water supply pipe wall. 3, drainage pump impeller or drainage pump failure. |